Most no-cool calls in Dallas–Fort Worth come on the first hot weeks of the year or in the middle of a heat wave. Before you call, these quick checks can save you a visit, and they'll help us fix it faster if you do need us.
1. Check the thermostat
Make sure it's set to Cool, the set temperature is below the room temperature, and the fan is on Auto. If the screen is blank, replace the batteries.
2. Check the air filter
A clogged filter is the most common cause of weak airflow and frozen coils. If you can't see light through it, replace it.
3. Check the breakers
Look for a tripped breaker for the AC and for the furnace or air handler. Reset it once. If it trips again, leave it off and call us; something is shorting.
4. Look at the outdoor unit
Is the fan spinning and the unit humming? If it hums but the fan doesn't spin, a failed capacitor is likely. Turn the system off at the thermostat so the compressor isn't damaged, and call.
5. Check the drain line
Many systems have a float switch that shuts the AC off when the condensate drain backs up. Water in the drain pan or a wet ceiling stain near the unit points to a clogged drain.
When to turn it off and call right away
- Ice on the refrigerant lines or indoor coil
- A burning smell, buzzing or grinding
- Water leaking through a ceiling
- The breaker trips again after one reset
We answer 24/7 at (214) 952-4247.
Frequently asked questions
Is it normal for my AC to run all day in August?
On 100°F days a correctly sized system may run almost constantly in the afternoon and still only hold about 20 degrees below the outdoor temperature. If the house keeps getting warmer, or it's running all night too, something is wrong.
Can I add refrigerant myself?
No. Refrigerant isn't used up; if it's low there is a leak. Handling refrigerant requires EPA certification, and topping it off without fixing the leak just postpones the problem.
Why is there ice on my AC lines?
Ice usually means poor airflow (dirty filter, blocked return, failing blower) or low refrigerant. Turn the cooling off, run the fan only to thaw it, and call for service.